F8 Medical Portable ICU ECG Room Multi
F8 Medical Portable ICU ECG Room Multi-Parameter 12.1 Inches Vital Signs Cardiac Patient Digital Blood Pressure Monitor
Basic Info.
Model NO. | F8 |
Central Station | Optional |
Upright Handle | Easy to Carry |
SpO2 | Optional |
Dimension | 375mm(W)*330mm(H)*180mm(D) |
Printer | Built-in 50mm Thermal Printer (Option) |
Battery | Rechargeable Battery, 2.2 Ah 12V |
Display | 12.1′color TFT LCD Screen |
Optional Configuration | Touch Screen, Printer, Trolley, Wall-Mount |
Transport Package | Export Carton Package |
Specification | CE, ISO |
Trademark | WANROOEMED |
Origin | China |
HS Code | 94029000 |
Production Capacity | 1000PCS/Month |
Product Description
F8 Medical Portable ICU ECG Room Multi-Parameter 12.1 Inches Vital Signs Cardiac Patient Digital Blood Pressure MonitorThe F8 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.An optional USB Mouse/Keyboard control eases navigation and data entry.An optional HDMI output eases observation from a long distance.The unique Accessory Box design can keep the accessories in order at the backside of the monitor.
multi-parameter patient monitor Features:
1. 12.1'color TFT LCD screen2. Acoustic and visual alarm3. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG4.Drug calculation and titration table5..Real time ST segment analysis, pacemaker detection and Arrhythmia analysis6. Suitable for monitoring adult, pediatric and neonatal patient7. Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event8. Isolated against defibrillation effectmulti-parameter patient monitor Standard Configuration: 3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBPmulti-parameter patient monitor Optional Configuration: Touch screen, Printer, Trolley, Wall-moun
Physical Specifications | ||
Dimension and weight | Dimension | 375mm(W)*330mm(H)*180mm(D) |
Weight | standard configuration: 4.4 kg | |
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W |
Power | 90VA | |
Temperature | 0-40ºC | |
Humidity | 0-93% non-condensing | |
Safety | Meet the requirements of IEC60601 series | |
Patient range | Adult, neonate and pediatric patients | |
Performance Specification | ||
Display | 12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display | |
Display mode | Standard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend | |
Interface | Parameter cable interfaceAC power input socket | |
Battery | Rechargeable battery, 2.2 Ah 12V | |
Alarm indicator | Visual on-display and integrated alarm lightAudible alarm and personated voice reminding alarm | |
Data storage | 240 hours monitoring data1024 NIBP records storage 1024 alarm event | |
Printer | Built-in 50mm thermal printer (option), 2 traces, print speed 25mm/s & 50mm/s print width:50mm | |
ECG | ||
Leads type | 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V | |
Sweep speed | 12.5mm/s, 25mm/s 50mm/s | |
Gain selection | ×0.25, ×0.5, ×1, ×2 | |
ECG waveform | 1 channels | |
Operation mode | Diagnostic, monitor, surgery | |
Heart rate range | 0 -300bpm | |
Accuracy | 1bpm or ±1% whichever is great | |
Alarm range | Audible and visual alarm, adjustable | |
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |
Protection | Against electrosurgical interference and defibrillation | |
Respiration (RESP) | ||
Method | Thoracic impedance | |
Operation mode | Auto | |
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |
Apnea alarm | Yes | |
Alarm | Yes, audible and visual alarm ,alarm events recallable | |
NIBP | ||
Method | Automatic oscillometric | |
Operation mode | Manual/Automatic/STAT |
Auto measure time | Adjustable | |
Measurement unit | mmHg / kPa selectable | |
Test interval | 1-480 minutes | |
Measurement range | Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg | |
Over-pressure protection | Double safety protection | |
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHgthe standard deviation shall be less than 8mmHG | |
Resolution | 1 mmHg | |
SPO2 | ||
Measurement range | 0%-100% | |
Resolution | 1% | |
Accuracy | ±2% (70-100%, adult/pediatric, non-motion )±3% (70-100%, neonate, non-motion )±3% (70-100%, adult/pediatric/neonate, motion )0-69% unspecified | |
Alarm range | 1-100% | |
Pulse rate | Pulse range: | 20-300bpm |
Accuracy: | ±3bpm(non-motion)±5bpm(motion ) | |
Temperature (TEMP) | ||
TEMP range | 0-50ºC | |
Resolution | 0.1 ºC | |
Accuracy | ±0.1ºC (excluding the sensor) | |
Channel | Single channel. |